Biotage is the leader in disk SPE technology. Able to handle the extraction of large sample volumes while maintaining fast flow rates with ease, Atlantic® SPE disks are ideal for the extraction of drinking water, groundwater and wastewater samples.
Compatible with both manual and highly controlled automated processing systems, Atlantic® SPE Disks are the only Certified for Automation disks available on the market today.
Part No. | Description | Pack Size | List Price | |
---|---|---|---|---|
47-2346-11 | Atlantic® 8270 One Pass Disks, 47 mm | 24 | 476 USD | Add to quote/cart |
47-2346-02 | Atlantic® C-18 Disks, 47 mm | 24 | 246 USD | Add to quote/cart |
47-2346-14 | Atlantic® Disk, C-18HC, 8 mm | 16 | 216 USD | Add to quote/cart |
47-2346-16 | Atlantic® Disk, Fiber, 8 mm | 16 | 151 USD | Add to quote/cart |
47-2346-15 | Atlantic® Disk, HLB-H, 8 mm | 16 | 288 USD | Add to quote/cart |
47-2346-06 | Atlantic® DVB Disks, 47 mm | 24 | 239 USD | Add to quote/cart |
FFAP-47-HT | Atlantic® Fast Flow Pre-Filter, 47 mm, Coarse 5.0 µm | 50 | 116 USD | Add to quote/cart |
FFAP-100-HS5 | Atlantic® Fast Flow Pre-Filter, 90 mm, Coarse 5.0 µm | 50 | 146 USD | Add to quote/cart |
FFAP-100-HS1 | Atlantic® Fast Flow Pre-Filter, 90 mm, Fine 1.0 µm | 50 | 110 USD | Add to quote/cart |
47-2346-13 | Atlantic® High Capacity C18 Disks, 47 mm | 24 | 305 USD | Add to quote/cart |
47-2346-10 | Atlantic® HLB-H Disks, 47 mm | 24 | 476 USD | Add to quote/cart |
47-2346-08 | Atlantic® HLB-L Disks, 47 mm | 40 | 428 USD | Add to quote/cart |
47-2346-09 | Atlantic® HLB-M Disks, 47 mm | 30 | 459 USD | Add to quote/cart |
49-2620-01 | One-Pass Carbon Cartridge Max Detect | 16 | 215 USD | Add to quote/cart |
Available in a range of media types, Atlantic® SPE Disks can be used in many EPA, EN and ISO methods, and are supported by multiple application notes.
This silica based C18 is end-capped to eliminate unpredictable secondary interactions with unreacted silanols. This reversed-phase media can be used for EPA Method 525.2 along with other drinking and wastewater methods.
Atlantic® High Capacity C18 SPE Disks provide added retention per disk for improved recovery of compounds that have weaker interactions with C18 media. Much like the original Atlantic C18 disk, the Atlantic High Capacity uses end-capped C18 to eliminate unpredictable secondary interactions with unreacted silanols. The disk can be used for drinking water applications such as EPA Method 525.2
Users have experienced higher recoveries for compounds such as dimethoate, 2,6-DNT, and 2,4-DNT. In the specific case of caffeine, a compound used as a drinking water tracer, recoveries more than doubled over standard C18 disks.
This disk contains media with 3 analyte retention mechanisms that significantly simplify the extraction process with the benefit of reduced labor, faster extraction times and elimination of high pH precipitates. This multi-mode disk chemistry enables the retention of over 100 target semi-volatile compounds with a sample pH of 2. Now acidic, neutral and basic analytes can be retained in a single water extraction step using this 47 mm disk. For extremely hydrophilic compounds, the optional Carbon Cartridge is placed after the One Pass disk to scavenge the sample effluent for light-end semi-volatile organics (LSVO). In this configuration all classes of compounds from EPA Method 8270/625 are automatically captured, eluted off the media and ready for drying and concentration.
The DVB (divinylbenzene) polymer is a pH independent reversed-phase media that is listed for use in the EPA drinking water method for a full suite of analytes, EPA Method 525.3.
The polymeric HLB (hydrophilic/Lipophilic Balanced) media in this disk comes in low, medium and high capacity formulations. These disks can be used for drinking and wastewater applications. Common applications include semi-volatile organic analysis and EPA Method 1694 (pharmaceuticals and personal care products), endocrine disruptors, and other emerging contaminants in wastewater and drinking water.
For use with the Atlantic SPE Disk, the Atlantic Prefilter increases sample flow rate without compromising recoveries. Perfect for dirty samples with lots of particulates, the Atlantic prefilter will accelerate sample throughput, and enables reproducible recoveries. These prefilters are “Certified for Automation” designed specifically for use with the Biotage® Horizon 5000 system.
These prefilters have proven to be effective in handling highly particulate laden aqueous samples. They are specifically designed and certified for use with the EZ Flow Disk Holder on the Biotage® Horizon 5000 system and are available in a 1 micron and 5 micron size.
Biotage is the Global Go-To Separations Company, supporting customers from drug discovery and development through to diagnostics and analytical testing with intelligent and sustainable workflow solutions. Our expertise and top-tier separation solutions play a key role in streamlining our customers’ workflows and improving their outcomes. Headquartered in Sweden, Biotage operates globally with 700 employees, serving over 80 countries. Our company is listed on NASDAQ Stockholm (BIOT).
Copyright © 2024 Biotage