Reversed phase flash chromatography is a very effective purification technique for polar, ionizable and highly lipophilic compounds which cannot easily be separated by normal phase techniques. Biotage supplies pre-packed purification cartridges featuring high performance Biotage® Sfär C18 silica (formally known as HP-Sphere C18, or SNAP ULTRA C18) for a range of Biotage development and scale up flash purification platforms to support a range of different chemistries and scale up purification scenarios. This silica stationary phase has been used for nearly 10 years in validated cGMP processes worldwide and provides a unique mix of high loading capacity and resolution in packed cartridges.
Use the cartridge selector below to quickly identify compatible cartridges for your purification platform and / or view available cartridges by size. Development and process development scale cartridges intended for use on Biotage® Selekt or our larger scale development platform Biotage® Isolera LS connect to the system via universal Luer-lock style connectors. Cartridges for our larger process development and scale up systems Biotage® Flash 75 / Flash 150 or Flash 400 systems require a compression module which is provided with the system, or available as a spare part (links open in a new window).
For over 20 years Biotage has been at the forefront of enabling flash purification technologies. Sfär C18 high performance silica for reversed phase purification significantly adds another and complimentary powerful solution when the most demanding of purification challenges presents itself.
Moving from lab scale to large scale comes with a number of additional considerations. Biotage® Isolera LS, Flash 75, 150 and 400 systems are extremely tough, economically viable scale-up purification systems that have been developed for this purpose. With the Biotage approach, scaling up flash purification methods is straightforward. Any method developed using a Biotage lab scale cartridge can be transferred to a larger cartridge using the scale-up factors. Once the development cartridge is determined, the lab scale method can be replayed, providing peak elution profiles for the expected scale up run which are suitable for further optimization if needed. Furthermore, Isolera LS comes with software that can automatically create linear gradients from TLC Rf spots; and then automatically convert those linear gradients into step gradients for application on a larger scale. Each of the larger flash systems may be configured with either ‘M’ or ‘L’ cartridge capability to further increase its flexibility and range.
Key supplier to industry for over 20 years, used in numerous patents and cGMP processes.
Purification from grams in development through to multi kilogram quantities of product for pre-clinical and commercial production campaigns.
Stationary phase silica is clean, inert and deployed to support the most demanding of purification goals.
With lot control, an extensive QA / QC documentation package including Safety Data sheets, ISO 9001 / 14001 registration certification, BSE / TSE statement, shelf-life statements, retest guidance, storage recomendations and more, Biotage silicas are deisnged for industry and professional scale up campaigns.
Part No. | Description | Pack Size | List Price | |
---|---|---|---|---|
FSUD-0401-0012 | Biotage® Sfär C18 D Duo 100 Å 30 µm 12 g | 2 | 162 USD | Add to quote/cart |
FSUD-0401-0120 | Biotage® Sfär C18 D Duo 100 Å 30 µm 120 g | 2 | 830 USD | Add to quote/cart |
FSUD-0401-0240 | Biotage® Sfär C18 D Duo 100 Å 30 µm 240 g | 1 | 1171 USD | Add to quote/cart |
FSUD-0401-0030 | Biotage® Sfär C18 D Duo 100 Å 30 µm 30 g | 2 | 373 USD | Add to quote/cart |
FSUD-0401-0400 | Biotage® Sfär C18 D Duo 100 Å 30 µm 400 g | 1 | 1403 USD | Add to quote/cart |
FSUD-0401-0006 | Biotage® Sfär C18 D Duo 100 Å 30 µm 6 g | 2 | 116 USD | Add to quote/cart |
FSUD-0401-0060 | Biotage® Sfär C18 D Duo 100 Å 30 µm 60 g | 2 | 497 USD | Add to quote/cart |
FSUL-0401-1850 | Biotage® SNAP Ultra C18 1850 g, 1/cs | 1 | 4277 USD | Add to quote/cart |
FSUL-0401-0950 | Biotage® SNAP Ultra C18 950 g, 1/cs | 1 | 2375 USD | Add to quote/cart |
FSUL-0401-50150 | Cartridge, (1) HP-Sphere C18 FLASH 400L | 1 | Add to quote/cart | |
FSUL-0401-50070 | Cartridge, (1) HP-Sphere C18 FLASH 400M | 1 | Add to quote/cart | |
FSUL-0401-25150 | Flash 150L Cartridge with HP-Sphere C18 | 1 | Add to quote/cart | |
FSUL-0401-25070 | Flash 150M Cartridge with HP-Sphere C18 | 1 | Add to quote/cart | |
FSUL-0401-19070 | Flash 75L Cartridge with HP-Sphere C18, 1/pk | 1 | Add to quote/cart | |
FSUL-0401-19040 | Flash 75M Cartridge with HP-Sphere C18, 1/pk | 1 | 2248 USD | Add to quote/cart |
SEL-2EV - Two Channel, Extended Collection Bed, UV Detector
Biotage is the Global Go-To Separations Company, supporting customers from drug discovery and development through to diagnostics and analytical testing with intelligent and sustainable workflow solutions. Our expertise and top-tier separation solutions play a key role in streamlining our customers’ workflows and improving their outcomes. Headquartered in Sweden, Biotage operates globally with 700 employees, serving over 80 countries. Our company is listed on NASDAQ Stockholm (BIOT).
Copyright © 2024 Biotage