Biotage AFFINILUTE™ MIP products offer analytical chemists ultimate selectivity compared with standard solid phase extraction techniques. Unlike other methods, AFFINILUTE MIP products rely on the specific molecular structure of the analyte for targeted capture resulting in exceptional clean up. AFFINILUTE MIP columns combine high affinity with standard flow through sample preparation methodology.
Biotage® ACT (Anti Cross Talk) Plate Adapter is a novel (patent pending) solution to the phenomenon of hot spot cross contamination, or cross talk, during evaporation.
Extrahera™ is a powerful, user friendly automation system for Supported Liquid Extraction (SLE), Solid Phase Extraction (SPE), Phospholipid Depletion (PLD) and Protein Precipitation (PPT) based methods, in plate or column formats.
The Biotage® Horizon SmartPrep is designed for simple automation of manual solid phase extraction (SPE) methods. Up to 12 samples per SmartPrep System can be run. To control the SmartPrep System, choose the front touch screen or the intuitive SmartPrep software. Run the same method or different methods for each of the 12 samples.
Biotage® PRESSURE+ manifolds deliver positive pressure, parallel processing for 96 well plates, 1 mL 3 mL and 6 mL column formats. The systems utilize a consistent, uniform flow of positive pressure to move both low and high viscosity liquids through SPE plates and columns.
The Biotage® Solvent Recovery SVOC is designed to condense and collect solvent vapors which are generated when using the DryVap® concentration system.
Designed for high throughput laboratories, the Biotage® SPE Dry 96 and Biotage® SPE Dry 96 Dual Sample Concentrator Systems provide efficient solvent evaporation in microplate format and are compatible with 24-, 96- and 384-well collection plates. Heated gas flow from above and below the collection plate ensures efficient solvent evaporation.
Biotage® VacMaster™ Sample Processing Manifolds allow up to 10 (VacMaster-10) or 20 (VacMaster-20) SPE or filtration columns to be processed simultaneously under vacuum. Unused ports are sealed when not required. Easy to use vacuum controls provide excellent sample flow control, leading to reproducible, reliable extraction conditions.
Biotage® VacMaster™-96 sample processing manifold has been designed with the needs of the bioanalytical scientist in mind. This manifold is ideal when processing 96-well SPE, supported liquid extraction or protein precipitation plates either manually or with an automated liquid handling system.
EVOLUTE® EXPRESS represents a leap forward in high throughput solid phase extraction. The EVOLUTE EXPRESS range of SPE columns and 96-well plates combine powerful EVOLUTE sorbent chemistry with innovative features that enhance productivity. With improved flow-through characteristics and by eliminating the need for conditioning and equilibration, samples can be prepared much faster using the simplified Load-Wash-Elute procedure.
EVOLUTE® HYDRO solid phase extraction plates combine robust, high quality EVOLUTE SPE sorbents with Hydro frit technology, enabling effective in-situ in-well hydrolysis of urine samples. Sample clean-up is performed in the same plate, without the need to transfer samples, saving time and reducing risky sample handling steps.
ISOLUTE® C18 is a retentive, non-polar sorbent for extraction of a range of analytes from aqueous samples using a non-polar retention mechanism.
ISOLUTE® C8 is a medium retentive, non-polar sorbent for extraction of a range of analytes from aqueous samples using a non-polar retention mechanism.
ISOLUTE® FILTER+ plates provide effective, workflow friendly filtration of biological samples, perfect for use prior to UPLC-MS/MS analysis. ISOLUTE FILTER+ plates are designed to prevent sample particulates from reaching the analytical UPLC column, protecting the analytical system from particulate build up over time. Versatile filtration for multiple sample matrices, including Urine samples Centrifuged tissue homogenates Pre-precipitated, centrifuged blood samples
ISOLUTE® HCX is a mixed-mode sorbent providing clean extracts for basic compounds from complex biological fluid samples using a dual retention mechanism.
ISOLUTE® HCX-3 is a mixed-mode sorbent providing clean extracts for basic compounds from complex biological fluid samples using a dual retention mechanism.
ISOLUTE® HCX-5 is a mixed-mode sorbent providing clean extracts for basic compounds from complex biological fluid samples using a dual retention mechanism.
ISOLUTE® HCX-Q is a mixed-mode sorbent providing clean extracts for strongly basic compounds (e.g. quaternary amines) from complex biological fluid samples using a dual retention mechanism.
ISOLUTE® HYDRO DME+ columns provide extremely efficient removal of matrix components and hydrolysis enzyme from urine samples, using a simple pass through workflow.
ISOLUTE® SLE+ Supported Liquid Extraction plates and columns are designed to provide stress free extraction of analytes from biological fluids, with high analyte recoveries, and clean, protein and phospholipid free extracts. Methods are easy to develop, and automation is simple.