Part No: PPS507Issued year: 2019File size: 0.65mbFile type: pdf
On a crisp December day, I travelled up to Queens, New York to speak with Dr. Aaron Muth from St. John’s University about his work in cancer research with Biotage lab equipment and specifically the SNAP Bio cartridges. As an Assistant Professor of Medicinal Chemistry, Dr. Muth and the members of his research group use our equipment every day. We chatted about his research, students, and the needs related to tools and equipment.
Part No: Issued year: 2003File size: 0.06mbFile type: pdf
Condensation reactions between N,N-dimethylformamide
diethyl acetal, DMFDEA, and compounds
comprising an activated methyl or methylene group
adjacent to a keto functionality form alkylaminopropenones.
These compounds have been used as
versatile intermediates for the synthesis of a large
number of heterocycles both with conventional and
microwave heating.
Part No: P110Issued year: 2014File size: 0.25mbFile type: pdf
Corrosion costs the petroleum industry an estimated $1.3 billion in non-productive time, materials and labor annually. Imidazolines prepared from fatty acids and amines are a widely-used class of chemical corrosion inhibitor, due to excellent performance and ease of handling. However, commercial imidazolines are actually mixtures of several different chemical compounds, and the relative proportions of these species can have a large impact on both corrosion inhibition and product physical properties. The absence of gold standard analytical methods to characterize the active ingredients in imidazoline formulations limits the understanding of the chemistry of these materials. It is for this reason that a SPE-LC-MS method was developed to supplement the chemical information afforded by bulk testing / wet chemistry methods. It is anticipated that this method will have significant impact in the formulation of new corrosion inhibitors for oilfield applications as well as the quality control of finished products in manufacturing.
GCC 2014
Part No: AN003-HORIssued year: 2009File size: 0.86mbFile type: pdf
This study shows that the SPE-DEX® 4790 Automated Extractor system can process water samples containing suspended particulate matter, up to 1000 mg, for the analysis of PAH’s. As PAH’s are found in both the dissolved and particulate phase of the water sample, it is important to be able to handle “whole” water samples such that the particulate matter in the water sample is retained and extracted with the SPE disk. This filtration method ensures that the PAH’s found in the dissolved phase, and those adsorbed onto the particulate matter are properly
extracted.
Part No: P116Issued year: 2014File size: 0.45mbFile type: pdf
This poster details current sample preparation strategies for aminoglycoside antibiotics in meat developed in a collaborative effort with Biotage and Tyson Foods, Inc. Springdale Corporate Laboratory to optimize analyte recovery (>70%), minimize analyte suppression and maintain acceptable method precision.
FAST LC-MS 2014
Part No: P070Issued year: 2014File size: 0.55mbFile type: pdf
This poster describes a strong cation exchange SPE protocol for extraction of Vitamin B3 (Niacin) and related metabolites from serum.
The ISOLUTE SCX-3 96 well plate format demonstrated as a viable option for serum measurements over a relevant concentration range in clinical diagnostics.
It is anticipated that strategies presented in this poster would be of broad-based interest to clinical laboratories focused on combining parent/metabolite assays into a single analysis.
MSACL 2014
Part No: AN814Issued year: 2014File size: 1.19mbFile type: pdf
This application note describes the extraction of Vitamin B3 (Niacin, nicotinic acid) and its key metabolites from serum using a strong cation exchange SPE retention mechanism. High reproducible analyte recoveries are achieved.
Part No: P052Issued year: 2013File size: 0.48mbFile type: pdf
Pain management therapy warrants constant monitoring of therapeutic levels of prescribed drug levels in patient urine samples. The number of samples being submitted for analysis has increased dramatically in the last 10 years with improvements in high throughput automated screening capabilities. Patient samples analysis is complicated by the need for an effective sample preparation methodology that can extract target analytes from complex matrices with good efficiency. Further complicating the process is the need to enzymatically hydrolyse the glucoronidated metabolites prior to extraction from the urine matrix. A fully automated sample preparation process using a TECAN Freedom EVO® 100 was designed to incorporate both the enzymatic hydrolysis and subsequent sample preparation assay as one continuous workflow. Supported Liquid Extraction (ISOLUTE SLE+) which offers an efficient alternative to traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) techniques was used to extract a suite of pain management drugs from spiked urine samples. A recovery and quantitation assay was run on the TECAN Freedom EVO® 100 using mock patient samples to demonstrate utility of automation process.
MSACL, Pain Management, Biotage, SPE, SLE, LLE, Supported Liquid Extraction, Drugs, MSACL, San Diego, 2013
Part No: Issued year: 2014File size: 0.88mbFile type: pdf
This poster presents the synthesis of peptidoglycan fragments where the coupling of peptides and carbohydrates was achieved using microwave heating. The fully automated total synthesis of a complex branched peptide is also presented. The fragments were synthesized using Biotage® Initiator+ SP Wave, Biotage® Syro Wave™ and Biotage® Initiator+ Alstra™ respectively. Presented at EPS, Sofia, 2014.
Part No: P047Issued year: 2012File size: 0.6mbFile type: pdf
The potential harm caused by synthetic cannabinoids is a significant concern since exposures and reports of human fatalities due to these substances is widespread [5]. Detection of these relatively new type designer drugs in blood is essential in forensic toxicology, other scientific and medical fields.
Cannabinoids, SLE, SLE+, Supported Liquid Extraction,
Part No: AN818.v1Issued year: 2014File size: 1.54mbFile type: pdf
This application note describes the extraction of ethyl glucuronide and ethyl sulfate from human urine using ISOLUTE® NH2 solid phase extraction columns. The method has been applied real patient samples that had been previously analyzed with a validated referee method. The results of the orthogonal measurements agreed, to provide similar diagnostic values.
Part No: P144Issued year: 2016File size: 0.6mbFile type: pdf
The ability to extract a broad range of different drugs from a biological matrix allows for the expedited analysis of a patient sample using LC-MS/MS. Typically small molecules are extracted from matrices like urine based on their polarities. A fast and reliable sample preparation method that could be implemented to extract drugs of different polarities from urine could be used as a screening tool to quickly identify the presence of illicit drugs in patient samples using LC-MS-MS.
This poster demonstrates the utility of supported liquid extraction for the extraction of over 30 different acidic, basic and neutral drugs in urine prior to LC-MS/MS.
MSACL 2016
Part No: AN099-HORIssued year: 2014File size: 2.06mbFile type: pdf
Aflatoxins, a mold largely produced by Aspergillus flavus and Aspergillus parasiticus1 are commonly tested mycotoxins found naturally in a wide range of agriculture crops and food products. Due to their harmful effects on human health, animal health, and global trade, aflatoxins are regulated in most countries and have established global limits in a wide variety of matrices.
Part No: P035Issued year: 2012File size: 0.26mbFile type: pdf
Vitamin D deficiency can result in various health issues such as osteoporosis, liver and kidney problems and is associated with increased risk of cancers and multiple
sclerosis. From this standpoint vitamin D analysis has extremely important clinical relevance. This poster presents a novel method for the extraction of 25 hydroxyvitamin D demonstrating acceptable validation parameters from serum calibrators and DEQAS supplied samples using ISOLUTE SLE+.
Part No: P109Issued year: 2014File size: 0.43mbFile type: pdf
This poster describes a supported liquid extraction method for extraction of a class of novel psychoactive substances (NBOMes) with analysis using laser diode thermal desorption (LDTD) MS/MS. Samples are oral fluid collected using Salivettes.
TAMS 2014